19'' 6U Chassis page 48/71
• Set the object: mgnt2CtrlChassisShutDown
Location: ...\microsens \mgnt2\mgnt2Hardware \mgnt2controls\
• Using a command in the CLI
• Enter the command shutdown (or sd) in the CLI
In all the cases, the LEDs of the MGNT are switched OFF when the MGNT is properly
stopped. Then, you can unplug the MGNT and plug it again in the MS430502M chassis.
It is necessary to wait at least 10 seconds before plugging again the MGNT.
Visual indications:
The colour sequence of the front panel LEDs are:
MGNT
SW LED: Off (few seconds) > Orange (less than 1 second) > Green
HW LED: Red (about 1 second) > Green
Generic slot MS
Refer to relevant MS User Manual.
End procedure
Power Off/On
The last method of reset is to power down the MS430502M chassis for a few moments
and power up again. This is traffic affecting and all equipped modules are reset. The
manager is unavailable for approximately 35 seconds.
Procedure
There is no on/off switch on the MS430502M chassis, powering down/up is achieved by
disconnecting/connecting the -48V supply(s) on the front panel.
• Power Down:
Before powering down the complete chassis, it is mandatory to stop the MGNT
software.
There are several ways to stop the MGNT software:
• Using the test button on the front panel. Push up the test button for 10
seconds.
• Using a SNMP object
Set the object mgnt2CtrlChassisShutDown
Location: ...\microsens \mgnt2\mgnt2Hardware \mgnt2controls\
• Using a command in the CLI. Enter the command shutdown (or sd) in the CLI.
In all the cases, the LEDs of the MGNT are switched OFF when the MGNT is
properly stopped.
Remove the -48V supply(s) on the front panel.