Set the port number for data transmission.
When serial port stops data transmission for a defined period of time
(Idle Timeout), the connection will be closed and the port will be freed
and try to connect with other hosts. 0 indicate disable this function.
Factory default value is 0. If Multilink is configured, only the first host
connection is effective for this setting.
The serial device will send TCP alive-check package in each defined time
interval (Alive Check) to remote host to check the TCP connection. If the
TCP connection is not alive, the connection will be closed and the port will
be freed. 0 indicate disable this function. Factory default is 0.
The number of Max connection can support simultaneous connections are
5, default values is 1.
Service Mode – TCP Client Mode
In TCP Client Mode, device can establish a TCP connection with server by the
method you set (Startup or any character). After the data has been transferred,
device can disconnect automatically from the server by using the TCP alive
check time or Idle timeout settings.
The following table describes the labels in this screen.